Certified test results
What we deliverEvery copper and fiber link certified to its rated category.
Why it matters
Certifier results are handed over, so performance is proven, not assumed.
Copper, fiber, risers and telecom rooms, designed by the team that runs systems on them.
installations over 10+ years
support for managed-service clients
Rated 4.9/5 by 110+ NYC corporations
Operating throughout New York
Structured cabling in NYC is planned around your stage: new build, move, cleanup or new systems.
Most cabling problems on construction projects are sequencing problems. As your low voltage contractor, we agree rough-in with the GC and electrician, so cable is in before walls close. The building's inspection and TCO dates set the cabling schedule. Every penetration is firestopped by the responsible trade.
Security and network systems are live in the new space on day one. In occupied offices, cable that tests to standard is reused.
Existing rooms become readable again, and dead cable leaves the pathways. Racks, patch panels, cable management, grounding and power are laid out so maintenance is straightforward.
Cameras, access control, intercom, PA and lighting control are planned on one cable schedule. When a camera will not come online, one team tests from switch port to device, with no handoff between cabler and installer.
Every run is tested, labeled and recorded, so faults are found in minutes.

Every copper and fiber link certified to its rated category.
Certifier results are handed over, so performance is proven, not assumed.
Both ends of every cable, port and rack labeled on one scheme.
Any cable or port is identified at a glance.
Drawings of outlets, routes and telecom rooms as built.
Future upgrades start from what is in the walls, not from what was designed.
PoE budgets, UPS backup and dedicated circuits requested at design.
PoE draw fits each switch with headroom for heaters, IR illuminators and added devices. Locks run from dedicated, supervised power supplies, so a network outage does not affect egress.
Switches, firewalls and security appliances on Cisco Meraki or Alta Labs.
As a partner for both, we configure the active layer for the devices it carries.
A two-venue hospitality build, and a school that stayed open during the work.

cabling and fiber for two venues, carrying over 200 AI-powered cameras.
Structured cabling and fiber, low-voltage systems, integrated access control, IT infrastructure programming and bespoke occupancy software for Brooklyn Hall and Pacha (Five Development), carrying over 200 AI-powered cameras. 25+ technicians worked at once.

new low-voltage systems while the school stayed open.
Automated light controls (Cooper) and a PA system (AtlasIED), delivered through SPK/Lewis Construction and phased around the school day.
“Wiring job for our new office build out was done right. Low voltage runs are clean, nothing looks rushed or messy. Cameras are positioned exactly where we asked.”
Planning a fit-out or new build?
Get the cabling designed for the systems it will carry.
Choosing network cabling in NYC starts with what each run must carry and for how long.
| Cable | Typical use | Why choose it |
|---|---|---|
| Cat6 | Data outlets, readers, intercom stations, most cameras | Cost-effective for horizontal runs and current PoE devices |
| Cat6A | PTZ and multi-sensor cameras, dense PoE bundles, long-life fit-outs | More headroom for bandwidth and heat |
| Fiber optic cabling | Risers, IDF-to-MDF backbones, links between buildings | Distance and capacity copper cannot carry; fusion spliced or pre-terminated |
| Plenum-rated (any type) | Air-handling spaces | Required there by NYC code; confirmed per space before ordering |
Low-voltage circuits are installed to NEC Article 725 and the NYC Electrical Code.
Five steps, phased around operating hours in occupied offices, schools, venues and stores.
Device counts, cable categories, risers and PoE budgets, with our security design team.
Rough-in, riser and power agreed with your GC and electrician before walls close.
Cable pulled, terminated and dressed; racks and switches installed.
You receive certifier results, the labeling scheme and as-built drawings.
Devices configured, with a 12-month warranty and maintenance plans.
FAQs
Structured cabling cost in NYC depends on drop count, cable category, fiber, ceiling and riser access, and whether the building is occupied. We price from a site survey, and our guide to structured cabling cost explains the drivers.
A structured cabling system has six subsystems under the ANSI/TIA-568 standards: entrance facilities, the equipment room (MDF), backbone cabling, telecommunications rooms (IDF), horizontal cabling and the work area. The riser backbone is usually fiber, and horizontal runs are Cat6 or Cat6A from the IDF to each device.
Yes, we upgrade data cabling in occupied offices by phasing work around business hours. Cable that tests to standard is reused, and abandoned cable is removed.
To choose a structured cabling contractor, ask for four things: licensing and insurance, certified test results for every link, as-built drawings at handover, and one team accountable for the devices on the cable.
Yes, we provide network cabling in Manhattan, Brooklyn, Queens, the Bronx and Staten Island, from our office in Midtown Manhattan near Bryant Park.
Share your drawings or walk us through the building. We'll show how the cabling connects to your integrated systems.